LVD & EMC Directives: CE for Electrical Products from India

For most appliances, adapters, luminaires and IT products, CE marking comes down to two directives: the Low Voltage Directive (safety) and the EMC Directive. Both usually allow self-declaration, with no Notified Body, as long as your EN test reports and technical file are sound. PCN builds on your IEC, CB and BIS data to keep testing lean.

Get an LVD / EMC QuoteWhatsApp Us

LVD and EMC at a Glance

Low Voltage Directive2014/35/EU, applied since 20 April 2016: electrical safety of equipment rated 50–1,000 V AC or 75–1,500 V DC
EMC Directive2014/30/EU, applied since 20 April 2016: electromagnetic emissions and immunity of apparatus and fixed installations
Who decides complianceThe manufacturer. The LVD has no Notified Body route; the EMC Directive allows an optional Notified Body review
Usual routeModule A internal production control: test, technical file, EU declaration of conformity, CE marking
Presumption of conformityOnly harmonised standards published in the Official Journal of the EU
Radio productsCovered by the Radio Equipment Directive 2014/53/EU, which includes safety and EMC
Usually also neededRoHS 2011/65/EU, and often WEEE, ErP ecodesign and energy labelling

Which Products Are Covered

Almost every mains-powered electrical product sold in the EU falls under both directives, together with many battery-powered products for EMC. Typical products PCN handles include:

  • Kitchen and household appliances
  • Chargers, adapters and SMPS
  • LED lamps, drivers and luminaires
  • IT and AV equipment
  • Switchgear and control panels
  • Power tools
  • Fans, heaters and air coolers
  • Pumps and motors
  • Cables, extension leads and plugs
  • Inverters and UPS units

Products rated below 50 V AC or 75 V DC fall outside the LVD; their safety is covered by the General Product Safety Regulation (EU) 2023/988, which has applied since 13 December 2024. They still need EMC compliance if they can cause or be affected by electromagnetic disturbance.

Essential Requirements

LVD: safety

The equipment must protect people, domestic animals and property from electrical, mechanical, fire, chemical, radiation and other hazards when used as intended and in foreseeable conditions.

EMC: emissions

The equipment must not generate electromagnetic disturbance above levels that let radio, telecom and other equipment work as intended.

EMC: immunity

The equipment must have adequate immunity to the disturbances it can expect in its intended environment, such as electrostatic discharge, surges and radiated fields.

Common Harmonised Standards

Product typeTypical standards
Household appliancesEN 60335-1 and the relevant EN 60335-2 part; EN 55014-1/-2; EN 61000-3-2 and -3-3
IT, AV and chargersEN IEC 62368-1; EN 55032 and EN 55035; EN 61000-3-2 and -3-3
LightingEN 60598 series, EN 61347 (control gear); EN IEC 55015 and EN 61547
Power toolsEN 62841 series; EN 55014-1/-2
Industrial equipmentEN 61000-6-2 and EN 61000-6-4, or product-specific standards

Use the edition currently cited in the Official Journal. Older editions may no longer give a presumption of conformity. IEC CB scheme reports are a strong base, but EU common modifications and the EN edition must be covered.

The Technical File

  • General description of the product and its intended use
  • Design drawings, circuit diagrams, PCB layouts and a list of critical components with their certifications
  • Risk assessment covering the LVD safety objectives and the EMC analysis
  • List of harmonised standards applied, and solutions used where standards were not applied in full
  • Test reports for safety and EMC
  • Copy of the EU declaration of conformity, labels and instructions

Keep the technical file and declaration for 10 years after the last unit is placed on the market, and provide them to market surveillance authorities on request.

EU Declaration of Conformity and CE Marking

The EU declaration of conformity names the manufacturer, identifies the product, lists every directive or regulation that applies (often LVD, EMC, RoHS and ErP together in one declaration) and the standards used, and is signed by the manufacturer. CE marking can only be affixed after the conformity assessment is complete, and must be visible, legible and indelible, at least 5 mm high.

Obligations for Indian Exporters

  • Labelling: manufacturer name, trade name or mark and postal address, plus the EU importer’s details, and a type, batch or serial number.
  • Instructions and safety information in the language of each EU country where the product is sold.
  • Responsible person in the EU: under the Market Surveillance Regulation (EU) 2019/1020, products under these directives need an EU-based economic operator, such as the importer or an authorised representative, whose details appear on the product.
  • Online sales: listings on EU marketplaces must show the manufacturer and EU responsible person details.

How PCN Handles It

  1. Standards. We identify every directive and the current harmonised standards for your product.
  2. Gap review. We check your IEC, CB, BIS and existing test reports for EN deviations.
  3. Testing. We arrange missing safety and EMC tests at accredited laboratories.
  4. Technical file. We compile the file, risk assessment and EU declaration of conformity.
  5. Labels. We check CE marking, manufacturer, importer and responsible person details.

LVD and EMC FAQs

Do I need a Notified Body for LVD or EMC?

Usually not. The LVD has no Notified Body route, and under the EMC Directive the manufacturer can self-declare using harmonised standards. A Notified Body review under EMC is optional.

Can I use my CB or IEC test reports for CE?

They are a strong base, but EU common modifications and the EN edition cited in the Official Journal must be covered, sometimes with additional testing.

Do radio products need LVD and EMC?

No. Products with radio functions fall under the Radio Equipment Directive, which includes safety and EMC requirements.

What about low-voltage products below 50 V AC?

They fall outside the LVD. Their safety is covered by the General Product Safety Regulation (EU) 2023/988, and they still need EMC compliance where relevant.

How long must I keep the technical file?

Ten years after the product is placed on the market. Authorities can ask for it at any time during that period.

Do I need an EU representative?

Products under these directives need an EU-based economic operator, such as the importer or an authorised representative, under the Market Surveillance Regulation (EU) 2019/1020.

Sources

Last reviewed: 17 October 2026.

Requirements, portals and fees change often. PCN confirms the applicable rules for each product before quoting. Certificates are issued by the relevant authority, accredited certification body or notified body.

Get Your Free LVD / EMC Check

Send your product name, HS code and destination. Our Delhi team will confirm the route, testing and timeline within 48 hours.

Request a Quote

📞 +91 80109 05029 · ✉️ admin@pcnindiaglobal.com

Related: EU Certification · CE Marking · Machinery Regulation · UL / ETL (USA)