CDSCO Licence for Hearing Aids in India: Class B Registration and IEC 60118
A hearing aid amplifies and shapes sound for people with hearing loss, and its performance and safe output level directly affect the user. CDSCO regulates the hearing aid as a Class B device with the hearing-aid performance standards behind the licence. This guide covers the full CDSCO registration pathway for hearing aids under the Medical Devices Rules, 2017 — classification, licence route, the IEC 60118 series, the documents, the fees and the timeline. This guide explains CDSCO registration for hearing aids in India — risk class, licence forms, standards, documents, fees and timeline.
Is a CDSCO Registration Mandatory for Hearing Aids?
Yes. A hearing aid is a notified Class B medical device and cannot be manufactured, imported or sold in India without a CDSCO licence. A domestic manufacturer holds a Form MD-5 licence from the State Licensing Authority. An importer holds a Form MD-15 import licence through an Indian Authorised Agent. Behind-the-ear, in-the-ear and receiver-in-canal hearing aids fall within the framework.
Risk Classification of Hearing Aids
Hearing Aids are classified as Class B (low-to-moderate risk). A hearing aid is a device that compensates for a disability and whose sound output affects the user, placing it in Class B (low-to-moderate risk) under the First Schedule. Where a device could fall in two classes the higher class applies, and an accessory is classified in its own right. Always confirm against the current CDSCO classification list.
Which CDSCO Licence You Need for Hearing Aids
- To manufacture hearing aids in India (Class B) — apply in Form MD-3 to the State Licensing Authority (SLA). The licensing authority grants the licence in Form MD-5. A CDSCO-empanelled Notified Body audits the site. For Class A the audit is post-grant. For Class B the Notified Body conducts it before the licensing authority grants the licence.
Applicable Standards for Hearing Aids
Hearing aids are evaluated against the hearing-aid performance standards plus electrical safety:
- IEC 60118 series — electroacoustics: hearing aids (performance measurement and characteristics).
- IEC 60118-0 — measurement of electroacoustical characteristics. And IEC 60118-7 for production-test characteristics.
- IEC 60601-1 — where applicable to the electronics/charging.
- IEC 60601-1-2 — electromagnetic compatibility (EMC).
- Maximum-output / OSPL90 limits to protect against over-amplification.
- ISO 10993 series — biocompatibility of ear-contacting components.
Documents Required for CDSCO Registration of Hearing Aids
The core CDSCO dossier is the same for every medical device: the application on CDSCO’s online medical device portal, Device Master File, Plant Master File, ISO 13485 certificate, Essential Principles checklist, ISO 14971 risk file, labels and IFU, undertakings and the fee receipt. The full checklist, with what each document must contain, is in our CDSCO medical device registration guide. Below is what CDSCO specifically expects to see for hearing aids.
Device-Specific Documents for Hearing Aids
- IEC 60118 performance reports — gain, frequency response, distortion and maximum output (OSPL90).
- Electrical-safety / EMC and battery-charging evidence where relevant.
- Biocompatibility for ear-canal-contacting parts.
- Software / fitting-algorithm documentation where the device is programmable.
- Output-limiting evidence to prevent hearing damage.
Label & IFU Requirements Specific to Hearing Aids
Hearing-aid labelling and the IFU are checked for output and use information:
- Device name, model and style (BTE/ITE/RIC), and the maximum output level.
- Batch/serial identification and the date of manufacture.
- Battery type and, where programmable, the fitting/compatibility information.
- Cleaning, fitting and output-safety information in the IFU.
Medical Hearing Aid vs Consumer Amplifier
The line to get right is between a hearing aid — a medical device intended to compensate for hearing loss — and a personal sound amplifier marketed as a consumer gadget. If the product is intended to help hearing-impaired users, it is a Class B medical device and needs a CDSCO licence, whatever the marketing says. Programmable and app-controlled models add a fitting-software element that is assessed. Fix the intended use and the maximum-output limiting before drawing test reports.
Step-by-Step CDSCO Registration Process for Hearing Aids
Every device follows the same online filing route, which we walk through step by step in our complete CDSCO registration guide. For hearing aids, these are the steps that need the most attention:
- Confirm the classification. Fix the risk class against the CDSCO classification list and the First Schedule — Class B here — which decides the form, authority, fee and audit route.
- Site audit / inspection. A CDSCO-empanelled Notified Body audits the site. For Class A the audit is post-grant. For Class B the Notified Body conducts it before the licensing authority grants the licence.
CDSCO Registration Fees and Timeline for Hearing Aids
A complete Class B manufacturing file typically clears in about three to six months. An import (MD-15) file usually takes six to nine months. Every deficiency letter effectively restarts the clock. Unlike the old registration certificates, an MDR 2017 licence does not expire — it stays valid as long as you pay the retention fee (equal to the licence fee) every five years and meet the conditions of licence.
Common Mistakes That Trigger a CDSCO Query
Common query reasons for hearing-aid applications are:
- IEC 60118 performance data missing or not for the exact model.
- No maximum-output (OSPL90) limiting evidence.
- Programmable models with thin fitting-software documentation.
- Biocompatibility absent for ear-contacting parts.
- Free Sale Certificate scope not covering the model on import.
FAQs on CDSCO Registration for Hearing Aids
What CDSCO class is a hearing aid?
A hearing aid is Class B. A domestic manufacturer files Form MD-3 for an MD-5 licence from the State Licensing Authority. An importer files Form MD-14 for an MD-15 licence.
Which standard applies to hearing aids in India?
The IEC 60118 series for hearing-aid electroacoustic performance, with electrical-safety/EMC evidence for the electronics where relevant.
Is a consumer sound amplifier a medical device?
If it is intended to help people with hearing loss, yes — it is a Class B medical device and needs a CDSCO licence regardless of consumer-style marketing.
Does CDSCO require a factory audit?
Yes — for Class B manufacture a CDSCO-empanelled Notified Body audits the site before the licensing authority grants the MD-5 licence.
How long does hearing-aid registration take?
A complete Class B manufacturing (MD-5) file usually clears in about three to six months. An import (MD-15) file typically takes six to nine months.
Related CDSCO Registration Guides
Need end-to-end help? See our CDSCO registration services, or read these related guides:
- CDSCO Registration for Adhesive Bandages in India
- CDSCO Registration for Coronary Stents in India
- CDSCO Registration for COVID-19 Antigen Test Kits in India
Official references: Central Drugs Standard Control Organisation (CDSCO) and the CDSCO MD Online portal.
Related Compliance Guides
- CDSCO Licence for Blood Bags
- CDSCO Licence for Examination Gloves
- CDSCO Licence for Spinal Implants
- CDSCO Licence for BP Monitors
Need help? PCN India Global handles end-to-end CDSCO medical device registration for manufacturers and importers.
Related guides
- CDSCO Licence for Heart Valves in India: Class D Registration and ISO 5840
- CDSCO Licence for HIV Test Kits in India: Class D IVD Registration
- CDSCO Licence for Hospital Beds in India: Class B Registration and IEC 60601-2-52
- CDSCO Licence for Implantable Pacemakers in India: Class D Registration and ISO 14708
- CDSCO Licence for Medical Gloves in India: Surgical Gloves (Class B) and Examination Gloves (Class A)
- CDSCO Licence for Nebulizers in India: Class B Registration and ISO 27427
More Medical Devices Guides
- CDSCO Licence for HIV Test Kits in India: Class D IVD Registration
- CDSCO Licence for Guidewires in India: Class C Registration and ISO 11070
- CDSCO Licence for Heart Valves in India: Class D Registration and ISO 5840
- CDSCO Licence for Blood Glucose Test Strips in India: Class C IVD Registration
- CDSCO Licence for Hospital Beds in India: Class B Registration and IEC 60601-2-52
- CDSCO Licence for Enteral Feeding Tubes in India: Class B Registration and ISO 20695